MD.ai

Hanging Protocols

Open the right series in the right viewers automatically

A hanging protocol sets the viewer layout and chooses which series opens in each viewer, for example axial T1 on the left and axial T2 on the right for every brain MR. Admins create protocols for the project; everyone can switch between them.

Create a hanging protocol

Open Settings in the project sidebar. Under Hanging Protocols, click New.

Set Name: enter a Hanging Protocol Name.

Set Viewers Layout: choose the grid of viewers, up to 2 rows by 3 columns.

Set Series Selector for Viewers: for each viewer, describe the series to show. See Series selectors.

Set as Default: select "Set this hanging protocol as default for project" to apply it automatically when exams open, then click Create.

To edit, delete, or change the default protocol, click Manage.

Series selectors

Each viewer's selector can combine these criteria. A series must match all the criteria you fill in:

CriterionMatches
PlaneAXIAL, SAGITTAL or CORONAL (or NONE for any)
Series DescriptionText contained in the DICOM SeriesDescription (case-sensitive), or a regular expression in slashes, such as /^t2/i
LabelsSeries with annotations or model outputs of the chosen series- or image-scoped labels. Choose OR (any label), AND (all labels) or NOT (none of the labels).

How series are placed:

  • Each viewer shows the first matching series not already shown in another viewer, or the first match if all are shown.
  • A viewer with no match shows the exam's first series.
  • Viewers without a selector are filled with the remaining series.

Switch protocols

In the Navigation column's Series list, choose a protocol from the Hanging Protocol menu, or None to arrange series yourself.

Deleting a label also deletes the hanging protocols that use it.